Analysis of cytokinin nucleotides by capillary zone electrophoresis with diode array and mass spectrometric detection in a recombinant enzyme in vitro reaction

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F12%3A33142716" target="_blank" >RIV/61989592:15310/12:33142716 - isvavai.cz</a>

  • Alternative codes found

    RIV/61389030:_____/12:00385991 RIV/61989592:15110/12:33142716

  • Result on the web

    <a href="http://www.sciencedirect.com/science/article/pii/S0003267012012792" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0003267012012792</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.aca.2012.08.049" target="_blank" >10.1016/j.aca.2012.08.049</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Analysis of cytokinin nucleotides by capillary zone electrophoresis with diode array and mass spectrometric detection in a recombinant enzyme in vitro reaction

  • Original language description

    A capillary zone electrophoresis (CZE) method for separation of adenosine and N-6-isopentenyladenosine (cytokinin) nucleotides was developed, optimized and validated. Aqueous solutions of several amino acids were evaluated as the background electrolyte constituents. Separation of six nucleotides in less than 20 min with high theoretical plate number (up to 400 000 for isopentenyladenosine triphosphate) was achieved using a 100 mM sarcosine/ammonia buffer at pH 10.0. The detection limits of the CZE-UV method are in the low micromolar range (0.69-1.27 mu mol L-1). Good repeatability of migration times (within 1.3%), peak areas (within 1.8%) and linearity (R-2 }0.999) was achieved over the concentration range 5-1000 mu mol L-1. The method was used to assay the activity of the recombinant Arabidopsis thaliana isopentenyltransferase 1 (AtIPT1). Baseline separation of isopentenylated nucleotides by CE-ESI-MS using a volatile buffer (30 mM ammonium formate; pH 10.0) was accomplished. The iden

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    ED - Physiology

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)

Others

  • Publication year

    2012

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Analytica Chimica Acta

  • ISSN

    0003-2670

  • e-ISSN

  • Volume of the periodical

    751

  • Issue of the periodical within the volume

    NOV

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    6

  • Pages from-to

    176-181

  • UT code for WoS article

    000311013100021

  • EID of the result in the Scopus database