HPLC-ED of low-molecular weight brominated phenols and tetrabromobisphenol A using pretreated carbon fiber microelectrode
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F14%3A33152563" target="_blank" >RIV/61989592:15310/14:33152563 - isvavai.cz</a>
Result on the web
<a href="http://www.sciencedirect.com/science/article/pii/S0039914014000241" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0039914014000241</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2014.01.013" target="_blank" >10.1016/j.talanta.2014.01.013</a>
Alternative languages
Result language
angličtina
Original language name
HPLC-ED of low-molecular weight brominated phenols and tetrabromobisphenol A using pretreated carbon fiber microelectrode
Original language description
Electrochemically pretreated carbon fiber microelectrode was used to develop a simple, fast and sensitive HPLC-ECD method for the determination of brominated phenols. In addition to simple mono-, di- and tri-bromophenols (4-bromophenol, 2,4-dibromophenol, 2,6-dibromophenol, 2,4,6-tri-bromophenol) the possibility of electrochemical detection of 3,3 ',5,5 '-tetrabromobisphenol A in oxidation mode is reported for the first time. The isocratic separation was achieved within 14 min using ternary mobile phaseconsisting of 50 mM-phosphate buffer (pH 3.5), acetonitrile and methanol (35/15/50, v/v), and detection potential of E = +1450 mV (vs. Ag/AgCl). The carbon fiber microelectrode permitted to use high anodic potentials (up to +1800 mV vs. Ag/AgCl), the optimum analytical response was achieved at +1450 mV vs. Ag/AgCl. The limits of detection (LOD) for the studied analytes were within the range of 1.856.6 ng mL(-1). The developed method was applied to determination of brominated phenols in
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GAP206%2F12%2F0796" target="_blank" >GAP206/12/0796: Carbon microfiber electrodes modified by electrochemical surface treatment and nanostructured metal layers as cutting-edge HPLC-EC detectors</a><br>
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Talanta
ISSN
0039-9140
e-ISSN
—
Volume of the periodical
122
Issue of the periodical within the volume
MAY
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
7
Pages from-to
115-121
UT code for WoS article
000335636700018
EID of the result in the Scopus database
—