Contour interaction under photopic and scotopic conditions
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F18%3A73587543" target="_blank" >RIV/61989592:15310/18:73587543 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1167/18.6.5" target="_blank" >http://dx.doi.org/10.1167/18.6.5</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1167/18.6.5" target="_blank" >10.1167/18.6.5</a>
Alternative languages
Result language
angličtina
Original language name
Contour interaction under photopic and scotopic conditions
Original language description
In the present study, we asked whether contour interaction undergoes significant changes for different luminance levels in the central and peripheral visual field. This study included nine normal observers at two laboratories (five at Palacky University Olomouc, Czech Republic and four at the University of Houston, USA). Observers viewed a randomly selected Sloan letter surrounded by four equally spaced bars for several separations measured edge-to-edge in min arc. Stimuli were viewed foveally under photopic and mesopic luminances and between 5 degrees and 12 degrees peripherally for four different background luminances of the display monitors, corresponding to photopic, mesopic, scotopic, and dim scotopic levels. The extent of the contour interaction in the fovea is approximately 20 times smaller than in the periphery. Whereas the magnitude of foveal contour interaction markedly decreases with decreasing luminance, no consistent luminance-induced change occurs in peripheral contour interaction. The extent of contour interaction does not scale with the size of the target letter, either in the fovea or peripherally. The results support a neural origin of contour interaction consistent with the properties of center-surround antagonism.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30207 - Ophthalmology
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
JOURNAL OF VISION
ISSN
1534-7362
e-ISSN
—
Volume of the periodical
18
Issue of the periodical within the volume
6
Country of publishing house
US - UNITED STATES
Number of pages
11
Pages from-to
"5-1"-"5-11"