All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Time resolution of the SiPM-NUV3S

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F19%3A73595436" target="_blank" >RIV/61989592:15310/19:73595436 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.sciencedirect.com/science/article/pii/S0168900219305649" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0168900219305649</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.nima.2019.04.082" target="_blank" >10.1016/j.nima.2019.04.082</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Time resolution of the SiPM-NUV3S

  • Original language description

    Silicon photomultipliers (SiPMs)have become an interesting alternative to conventional and micro-channel plate photomultipliers, proving to be a very good option for Cherenkov light based time-of-flight detectors. The important characteristic for this application is the intrinsic time resolution for a wide range of wavelengths (from below 250nm up to about 600nm). We present a study of the time resolution of two SiPMs: a 3 × 3 mm2 FBK SiPM-NUV3S and a 3.5 × 3.5 mm2 STMicroelectronics prototype SiPM. The measurement was performed for two representative wavelengths (280nm and 420nm)under the variation of SiPM overvoltage and light intensity. The measured transition time spread (TTS)of the devices was (285±9)ps (FBK)and (154±20)ps (STM). The time resolution dropped with increasing mean number of photoelectrons (Npe)as σTTSNpe − [Formula presented] with saturation observed for high Npe. The obtained best time resolutions were (8±1)ps and (4±1)ps for the FBK and STM SiPM respectively at Npe of the order of 106 for 420nm photons. The results for the two wavelengths were comparable, with 280nm photons providing worse results at very high illumination.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    NUCLEAR INSTRUMENTS &amp; METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT

  • ISSN

    0168-9002

  • e-ISSN

  • Volume of the periodical

    935

  • Issue of the periodical within the volume

    AUG

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    5

  • Pages from-to

    51-55

  • UT code for WoS article

    000470063800008

  • EID of the result in the Scopus database

    2-s2.0-85065543073