Comparative Analysis of the Diagnostic Effectiveness of SATRO ECG in the Diagnosis of Ischemia Diagnosed in Myocardial Perfusion Scintigraphy Performed Using the SPECT Method
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F22%3A73613696" target="_blank" >RIV/61989592:15310/22:73613696 - isvavai.cz</a>
Result on the web
<a href="https://www.mdpi.com/2075-4418/12/2/297/htm" target="_blank" >https://www.mdpi.com/2075-4418/12/2/297/htm</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/diagnostics12020297" target="_blank" >10.3390/diagnostics12020297</a>
Alternative languages
Result language
angličtina
Original language name
Comparative Analysis of the Diagnostic Effectiveness of SATRO ECG in the Diagnosis of Ischemia Diagnosed in Myocardial Perfusion Scintigraphy Performed Using the SPECT Method
Original language description
There is a great need for early diagnosis of ischemic heart disease (IHD), the most common cause of which is haemodynamic disorders caused mainly by obstructive atherosclerosis of the coronary arteries. The diagnosis of IHD is usually made with the use of functional tests, which include resting ECG (R) or examination of significant perfusion disorders during exercise using the SPECT method. Despite the fact that the ECG (R) test is commonly used in cardiological diagnostics, it has a limited diagnostic value, especially in people with a low probability of coronary artery disease (CAD). In order to increase the effectiveness of the ECG (R) examination, SATRO ECG software, based on the single fibres heart activity model (SFHAM), was used to evaluate the electrocardiograms. The introduction of new classifiers from the available medical data to the analysis made it possible to evaluate the diagnostic efficacy of SATRO ECG (TOT) in predicting significant perfusion disorders in the exercise SPECT (TOT 2). These disorders are most often caused by obstructive atherosclerosis of the coronary arteries, which is the main cause of CAD. The database of 316 patients (219 men and 97 women, aged 57 +/- 10 years) was analyzed using resting and stress ECG, perfusion scintigraphy performed using the SPECT method, and SATRO ECG analysis. The diagnostic efficacy parameters of SATRO ECG (TOT) in predicting significant perfusion abnormalities in the exercise-induced SPECT (TOT 2) study were: sensitivity, 99%; specificity, 91%; concordance, 96%; and positive, 96%, and negative, 97%, predictive values. The Kappa-Cohen coefficient was 0.92, and the statistical significance coefficient was p < 0.001. These results indicate a statistically significant agreement in the diagnosis of IHD in both diagnostic methods used.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30218 - General and internal medicine
Result continuities
Project
<a href="/en/project/EF16_019%2F0000754" target="_blank" >EF16_019/0000754: Nanotechnologies for Future</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Diagnostics
ISSN
2075-4418
e-ISSN
—
Volume of the periodical
12
Issue of the periodical within the volume
2
Country of publishing house
CH - SWITZERLAND
Number of pages
13
Pages from-to
"297-1"-"297-13"
UT code for WoS article
000761437500001
EID of the result in the Scopus database
2-s2.0-85124100705