Crowding can impact both low and high contrast visual acuity measurements
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F22%3A73614073" target="_blank" >RIV/61989592:15310/22:73614073 - isvavai.cz</a>
Result on the web
<a href="https://www.nature.com/articles/s41598-022-20479-y.pdf" target="_blank" >https://www.nature.com/articles/s41598-022-20479-y.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/s41598-022-20479-y" target="_blank" >10.1038/s41598-022-20479-y</a>
Alternative languages
Result language
angličtina
Original language name
Crowding can impact both low and high contrast visual acuity measurements
Original language description
The adverse impact of adjacent contours on letter visual acuity is known as crowding but there is conflicting evidence that foveal crowding may be reduced or disappears under low contrast conditions. Potential differences in foveal crowding with contrast on clinical measurements of visual acuity, including test-retest repeatability, were assessed. Visual acuity was measured at the fovea on adult participants with normal vision under three different contrast levels (- 90, - 10 and - 5%). Three rows of 5 letters, each row differing in size by 0.05 logarithm of the minimum angle of resolution (logMAR) from largest to smallest were displayed at the center of a monitor. Crowding was varied by varying the separation between horizontally adjacent letters from 100% optotype size to 50%, 20% and 10% optotype size. Inter-row spacing was proportional to optotype size. Observers read the letters on the middle row only. Measurements continued by reducing the size of the letters until 3 or more errors were made and were repeated on two separate days. Visual acuity worsened as both letter contrast decreased and inter-optotype separation reduced (expressed as a percentage of letter width). When expressed in minutes of arc of separation the impact of crowding was the same across all contrasts. Crowding occurs for both high and low contrast charts and should be considered when assessing low contrast visual acuity. Test-retest repeatability showed little or no dependence on either contrast or inter-optotype separation.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10306 - Optics (including laser optics and quantum optics)
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Scientific Reports
ISSN
2045-2322
e-ISSN
2045-2322
Volume of the periodical
12
Issue of the periodical within the volume
1
Country of publishing house
GB - UNITED KINGDOM
Number of pages
9
Pages from-to
"16338-1"-"16338-9"
UT code for WoS article
000862059200081
EID of the result in the Scopus database
2-s2.0-85138984471