All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Effect of small sided game duration with floater player on internal and external load of female handball players

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15510%2F21%3A73609119" target="_blank" >RIV/61989592:15510/21:73609119 - isvavai.cz</a>

  • Result on the web

    <a href="https://sciendo.com/article/10.2478/pjst-2021-0020" target="_blank" >https://sciendo.com/article/10.2478/pjst-2021-0020</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.2478/pjst-2021-0020" target="_blank" >10.2478/pjst-2021-0020</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Effect of small sided game duration with floater player on internal and external load of female handball players

  • Original language description

    The present study deals with the effect of the duration of small-sided games (SSGs) with a floater player on the external (covered distance) and internal (heart rate) load of the elite female players. Material and methods. The research group consisted of nine professional elite female team handball field players (age 22.8 ± 4.5 years) playing in the first international league for female players in the Czech Republic. Their height was 170.4 ± 6.4 cm, weight 67.7 ± 9.2 kg, and maximal heart rate 200.2 ± 3.3 beats∙min-1. The duration of the SSGs was 4 (SSG4) minutes, 5 (SSG5) minutes, and 6 (SSG6) minutes. Results. The highest heart rate value of 177.2 ± 9.9 beats / minute resp. 88.5 ± 4.4% HRmax was measured in SSG5. The lowest mean heart rate values were measured at SSG6 of 172.01 ± 15.7 beats / min resp. 85.9 ± 6.8% HRmax. Most time 38 resp. 34% of the drill time, players were in the 85-90% HRmax load intensity zone of SSG4 and SSG5. There was a statistically significant difference in load intensity zones of 80-85% HRmax and ≥ 95% HRmax between SSG5 and SSG6 and p = .008 (η2p = 0.22) and .013 (η2p = 0.26), respectively. In the rating of perceived exertion (RPE) evaluation, there was a statistically significant difference in SSG6 and SSG4 p = .003 (η2p = 0.27) and between SSG6 and SSG5 p = .004 (η2p = 0.25). The total longest distance in SSG6 was 786.8 ± 41.9 m, but in the one-minute drill the longest average distance in SSG4 was 136.2 ± 21.1 metres per minute. Conclusions. SSGs with a floater are a suitable means for training technical and tactical activities in handball with an overlap into fitness training in women&apos;s handball. According to our results, the intensity of the load will not decrease if we increase the game time to six minutes and also the covered distance will not decrease during the game

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database

  • CEP classification

  • OECD FORD branch

    30304 - Public and environmental health

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2021

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Polish Journal of Sport and Tourism

  • ISSN

    1899-1998

  • e-ISSN

  • Volume of the periodical

    28

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    6

  • Pages from-to

    10-15

  • UT code for WoS article

  • EID of the result in the Scopus database

    2-s2.0-85122815118