3D printed chip for electrochemical detection of influenza virus labeled with CdS quantum dots
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F14%3A00217377" target="_blank" >RIV/62156489:43210/14:00217377 - isvavai.cz</a>
Alternative codes found
RIV/00216305:26620/14:PU107958
Result on the web
<a href="http://dx.doi.org/10.1016/j.bios.2013.10.031" target="_blank" >http://dx.doi.org/10.1016/j.bios.2013.10.031</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.bios.2013.10.031" target="_blank" >10.1016/j.bios.2013.10.031</a>
Alternative languages
Result language
angličtina
Original language name
3D printed chip for electrochemical detection of influenza virus labeled with CdS quantum dots
Original language description
In this study,we report a new three-dimensional (3D), bead-based microfluidic chip developed for rapid, sensitive and specific detection of influenza hemagglutinin. The principle of microfluidic chip is based on implementation of two-step procedure thatincludes isolation based on paramagnetic beads and electrochemical detection. As a platform for isolation process, streptavidin-modified MPs,which were conjugated via biotinylated glycan (through streptavidin--biotin affinity) followed by linkage of hemagglutinin to glycan, were used. Vaccine hemagglutinin (HAvaxi) was labeled with CdS quantum dots (QDs) at first. Detection of the isolation product by voltammetry was the end point of the procedure. The suggested and developed method can be used also fordetection of other specific substances that are important for control, diagnosis or therapy of infectious diseases.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/ED1.1.00%2F02.0068" target="_blank" >ED1.1.00/02.0068: Central european institute of technology</a><br>
Continuities
O - Projekt operacniho programu
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Biosensors and Bioelectronics
ISSN
0956-5663
e-ISSN
—
Volume of the periodical
54
Issue of the periodical within the volume
1
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
7
Pages from-to
421-427
UT code for WoS article
333071500064