Trace level voltammetric determination of Zn(II) in selected nutrition related samples by bismuth-oxychloride-multiwalled carbon nanotube composite based electrode
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F19%3A43915098" target="_blank" >RIV/62156489:43210/19:43915098 - isvavai.cz</a>
Alternative codes found
RIV/00216275:25310/19:39914669
Result on the web
<a href="https://doi.org/10.1016/j.microc.2018.12.053" target="_blank" >https://doi.org/10.1016/j.microc.2018.12.053</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.microc.2018.12.053" target="_blank" >10.1016/j.microc.2018.12.053</a>
Alternative languages
Result language
angličtina
Original language name
Trace level voltammetric determination of Zn(II) in selected nutrition related samples by bismuth-oxychloride-multiwalled carbon nanotube composite based electrode
Original language description
Bismuth-oxychloride-multiwalled carbon nanotube composite material was applied as surface modifier of glassy carbon electrode (BiOCl-MWCNT/GCE) for rapid and reliable trace level determination of Zn(II) in selected foodstuffs. The method development encompasses the optimization of electrode preparation including the transmission electron microscopic study of the modifier suspension, selection of the supporting electrolyte pH, the adjustment of the operation parameters of the SW-ASV measurements and the investigation of matrix effects. By the BiOCl-MWCNT/GCE recorded calibration curve showed an excellent linearity towards Zn reoxidation peak intensity in the concentration range from 2.50 to 80.0 μg LMINUS SIGN 1 with the calculated LOD of 0.75 μg LMINUS SIGN 1 which was associated with 120 s accumulation time and accumulation potential MINUS SIGN 1.40 V vs SCE in acetate buffer pH 4.5. A satisfactory repeatability expressed as relative standard deviation of 4.8% was obtained in the case of 10.0 μg LMINUS SIGN 1 Zn(II) in model solution. The Zn(II) reoxidation signal from BiOCl-MWCNT/GCE received by the optimized SW-ASV method was compared with those recorded with bare, classical bismuth-film, multiwalled carbon nanotubes and by in situ made advanced bismuth-film-MWCNTs working electrodes. The applicability of the proposed BiOCl-MWCNT/GCE based method was corroborated via measuring the target analyte in two nutrition related real samples: in a dietary supplement and in a brewer's yeast sample. Comparative flame atomic absorption spectrometric measurements verified the obtained results in the case of yeast sample.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Microchemical Journal
ISSN
0026-265X
e-ISSN
—
Volume of the periodical
146
Issue of the periodical within the volume
May
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
9
Pages from-to
178-186
UT code for WoS article
000463132100023
EID of the result in the Scopus database
2-s2.0-85059519711