Simultaneous determination of arsenic and uranium by the diffusive gradients in thin films technique using Lewatit FO 36: Optimization of elution protocol
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F21%3A43919641" target="_blank" >RIV/62156489:43210/21:43919641 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1016/j.talanta.2021.122234" target="_blank" >https://doi.org/10.1016/j.talanta.2021.122234</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2021.122234" target="_blank" >10.1016/j.talanta.2021.122234</a>
Alternative languages
Result language
angličtina
Original language name
Simultaneous determination of arsenic and uranium by the diffusive gradients in thin films technique using Lewatit FO 36: Optimization of elution protocol
Original language description
The sorption ability of Lewatit FO 36-DGT resin gel, which has been developed for arsenic determination, towards uranium was tested by batch experiments within this study for the first time. Since the uptake efficiency of uranium was 99.0 +- 0.4% and the maximum uptake capacity was not achieved even at the U spike of 1250 μg in the solution, the Lewatit FO 36 resin seems to be a suitable binding phase for DGT resin gels for the determination of uranium. The resin gel also does not display any significant sorption selectivity in favour of one element over another. A novel protocol for simultaneous elution of arsenic and uranium from Lewatit FO 36 resin gel was therefore proposed in this study. The elution efficiencies of 90.3 +- 3.9% and 85.2 +- 3.1% for As and U, respectively, were obtained using 5 mL of 1 M NaOH at 70 oC for 24 h. The comparison with the original elution protocol using microwave-assisted elution by 0.25 M NaOH and 0.17 M NaCl at 130 oC for 16 min indicates, that the novel elution protocol provides good results in the performance of arsenic elution and, in addition, allows simultaneous elution of uranium. Moreover, the elimination of NaCl from the elution process allows a fast and simple analysis of both elements using ICP-MS, and therefore, the Lewatit FO 36-DGT technique can become more commonplace among laboratories without the need to modify the analytical method as proposed in the original study.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Talanta
ISSN
0039-9140
e-ISSN
—
Volume of the periodical
228
Issue of the periodical within the volume
1 June
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
6
Pages from-to
122234
UT code for WoS article
000657101200052
EID of the result in the Scopus database
2-s2.0-85101956936