In Situ Investigation of the Cytotoxic and Interfacial Characteristics of Titanium When Galvanically Coupled with Magnesium Using Scanning Electrochemical Microscopy
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F21%3A43920349" target="_blank" >RIV/62156489:43210/21:43920349 - isvavai.cz</a>
Alternative codes found
RIV/00216305:26620/21:PU141711
Result on the web
<a href="https://doi.org/10.1021/acsami.1c10584" target="_blank" >https://doi.org/10.1021/acsami.1c10584</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/acsami.1c10584" target="_blank" >10.1021/acsami.1c10584</a>
Alternative languages
Result language
angličtina
Original language name
In Situ Investigation of the Cytotoxic and Interfacial Characteristics of Titanium When Galvanically Coupled with Magnesium Using Scanning Electrochemical Microscopy
Original language description
Recently, the cytotoxic properties of galvanically coupled Ti-Mg particles have been shown in different cells. This cytotoxic effect has been attributed mainly to Mg due to its tendency to undergo activation when coupled with Ti, forming a galvanic cell consisting of an anode (Mg) and a cathode (Ti). However, the role of the Ti cathode has been ignored in explaining the cytotoxic effect of Ti-Mg particles due to its high resistance to corrosion. In this work, the role of titanium (Ti) in the cytotoxic mechanism of galvanically coupled Ti-Mg particles was examined. A model galvanic cell (MGC) was prepared to simulate the Mg-Ti particles. The electrochemical reactivity of the Ti sample and the pH change in it due to galvanic coupling with Mg were investigated using scanning electrochemical microscopy (SECM). It was observed that the Ti surface changed from passive to electrochemically active when coupled with Mg. Furthermore, after only 15 min of galvanic coupling with Mg, the pH in the electrolyte volume adjacent to the Ti surface increased to an alkaline pH value. The effects of the galvanic coupling of Ti and Mg, as well as those of the alkaline pH environment, on the viability of Hs27 fibroblast cells were investigated. It was shown that the viability of Hs27 cells significantly diminished when Mg and Ti were galvanically coupled compared to when the two metals were electrically disconnected. Thus, although Ti usually exhibited high corrosion resistance when exposed to physiological environments, an electrochemically active surface was observed when galvanically coupled with Mg, and this surface may participate in electron transfer reactions with chemical species in the neighboring environment; this participation resulted in the increased pH values above its surface and enhanced generation of reactive oxygen species. These features contributed to the development of cytotoxic effects by galvanically coupled Ti-Mg particles.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
ACS applied materials & interfaces
ISSN
1944-8244
e-ISSN
—
Volume of the periodical
13
Issue of the periodical within the volume
36
Country of publishing house
US - UNITED STATES
Number of pages
10
Pages from-to
43587-43596
UT code for WoS article
000697282300119
EID of the result in the Scopus database
2-s2.0-85115104209