The current situation in the field of physicochemical parameters of honey from Brno region
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16270%2F10%3A00002935" target="_blank" >RIV/62157124:16270/10:00002935 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
čeština
Original language name
Aktuální situace v oblasti fyzikálně chemických parametrů medů brněnského regionu
Original language description
The basic physicochemical parameters were determinated of floral, honeydew and forest honey from Brno and surroundings. Samples (n = 42) were divided into groups, depending on where they were collected to samples from beekeepers, from retail stores and specialist stores (beekeping stores and health food stores). Using standard methods described in the Harmonized Methods of the International Commision for Honey were derminated electrical conductivity, hydroxymethylfurfural (HMF) content and diastase activity. HMF values for samples from retail stores ranged between 10.27 to 75.52 mg/kg, in samples obtained from beekeepers between 0.29 to 15.28 mg/kg and samples from specialized stores between 1.76 to 85.25 mg/kg. Diastase activity of the samples from retail stores ranging from 4.3 to 20.5 DN, samples from beekeepers between 10.28 to 20.4 DN and samples from specialized stores between 3.5 to 19.7 DN. Electrical conductivity of samples from retail stores were between 9.5 to 50.4 mS/m, sam
Czech name
Aktuální situace v oblasti fyzikálně chemických parametrů medů brněnského regionu
Czech description
The basic physicochemical parameters were determinated of floral, honeydew and forest honey from Brno and surroundings. Samples (n = 42) were divided into groups, depending on where they were collected to samples from beekeepers, from retail stores and specialist stores (beekeping stores and health food stores). Using standard methods described in the Harmonized Methods of the International Commision for Honey were derminated electrical conductivity, hydroxymethylfurfural (HMF) content and diastase activity. HMF values for samples from retail stores ranged between 10.27 to 75.52 mg/kg, in samples obtained from beekeepers between 0.29 to 15.28 mg/kg and samples from specialized stores between 1.76 to 85.25 mg/kg. Diastase activity of the samples from retail stores ranging from 4.3 to 20.5 DN, samples from beekeepers between 10.28 to 20.4 DN and samples from specialized stores between 3.5 to 19.7 DN. Electrical conductivity of samples from retail stores were between 9.5 to 50.4 mS/m, sam
Classification
Type
D - Article in proceedings
CEP classification
GM - Food industry
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2010
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Food Hygiene and Technology 40th Lenfelds and Hökls Days
ISBN
978-80-7305-121-1
ISSN
—
e-ISSN
—
Number of pages
4
Pages from-to
—
Publisher name
Veterinární a farmaceutická univerzita Brno
Place of publication
Brno
Event location
Brno
Event date
Jan 1, 2010
Type of event by nationality
EUR - Evropská akce
UT code for WoS article
—