A mechanical construction proposal of rehabilitation instrument for measurement and analysis of knee joint range

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62690094%3A18450%2F20%3A50017639" target="_blank" >RIV/62690094:18450/20:50017639 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21460/20:00345830 RIV/61989100:27240/20:10246827

  • Result on the web

    <a href="http://dx.doi.org/10.1109/EHB50910.2020.9279878" target="_blank" >http://dx.doi.org/10.1109/EHB50910.2020.9279878</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/EHB50910.2020.9279878" target="_blank" >10.1109/EHB50910.2020.9279878</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    A mechanical construction proposal of rehabilitation instrument for measurement and analysis of knee joint range

  • Original language description

    In the area of the rehabilitation, one of the most frequent tasks is a measurement of joint range. In the current time, protractors, goniometers and specialized systems with direct measurement are used to determine the joint range in static and dynamic measurements. Such systems lack accuracy and reproducibility of the results. In this paper, we introduce a mechanical construction solution of a novel instrument for measurement of joint range for knee geometry. In order to the device works properly, it is advantageous for it to be set to the correct measuring position before the measurement. The device is set in the correct position by aligning the axis of the through hole with a physiologically given point in the joint, and then the optical lines created by the line lasers are aligned with the other two physiological points on the given limb. The proposed device has the main advantages in electrical sensing and data visualization with wireless connection, it utilizes a line laser to instrument calibration and moveable construction may compensate limb curvatures. ©2020 IEEE

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

    <a href="/en/project/TL01000302" target="_blank" >TL01000302: Medical devices development as an effective investment for public and private entities</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    2020 8th E-Health and Bioengineering Conference, EHB 2020

  • ISBN

    978-1-72818-803-4

  • ISSN

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

    "Article number 9279878"

  • Publisher name

    Institute of Electrical and Electronics Engineers Inc.

  • Place of publication

    Virtual Iasi

  • Event location

    Romania

  • Event date

    Oct 29, 2020

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article