LoRaWAN-based IoT protocol for three levels central protection scheme in MT-HVDC networks with ANFIS-PSO restoration algorithm

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62690094%3A18450%2F23%3A50021056" target="_blank" >RIV/62690094:18450/23:50021056 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.sciencedirect.com/science/article/pii/S2352484723015378?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S2352484723015378?via%3Dihub</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.egyr.2023.11.013" target="_blank" >10.1016/j.egyr.2023.11.013</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    LoRaWAN-based IoT protocol for three levels central protection scheme in MT-HVDC networks with ANFIS-PSO restoration algorithm

  • Original language description

    A new three-level adaptive central protection scheme has been introduced for multi-terminal high voltage direct current (MT-HVDC) transmission grids. The primary protection is based on a differential relay, while two backup protection levels are proposed: a local dv/dt under-voltage relay and a centralized overcurrent relay at the AC grid side. The coordination of these three protection levels is managed based on a convenient coordination time. The communication between the central protection unit and the Fault Isolation Devices (FIDs) is established using the LoRaWAN-based Internet of Things (IoT) protocol. In case of fault clearance triggered by the third protection level, the faulty line is detected and isolated using the adaptive neuro-fuzzy inference system (ANFIS) algorithm. The restoration process of the healthy lines focuses on minimizing load shedding and line power loss. The protection scheme proposed in this article has been implemented and tested under various fault conditions using the MATLAB/Simulink (R) environment. The results demonstrate the effectiveness and efficiency of the proposed protection scheme in detecting and isolating faulty lines in MT-HVDC transmission grids, along with a rapid restoration technique.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20704 - Energy and fuels

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Energy Reports

  • ISSN

    2352-4847

  • e-ISSN

  • Volume of the periodical

    10

  • Issue of the periodical within the volume

    November

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    18

  • Pages from-to

    4556-4573

  • UT code for WoS article

    001120910900001

  • EID of the result in the Scopus database

    2-s2.0-85178998443