All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

BiOI: Self-Powered Humidity Sensor and Breath Monitor

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62690094%3A18470%2F25%3A50022517" target="_blank" >RIV/62690094:18470/25:50022517 - isvavai.cz</a>

  • Result on the web

    <a href="https://advanced.onlinelibrary.wiley.com/doi/10.1002/admt.202401988" target="_blank" >https://advanced.onlinelibrary.wiley.com/doi/10.1002/admt.202401988</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/admt.202401988" target="_blank" >10.1002/admt.202401988</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    BiOI: Self-Powered Humidity Sensor and Breath Monitor

  • Original language description

    The self-powered, adaptable, quick, and precise humidity sensors are required to measure humidity in the microenvironment. Here, a simple one-step wet chemical method is presented to prepare stacked layered bismuth oxyiodide (BiOI) nanoplates. The remarkable response and self-powered behavior of BiOI nanoplates-based humidity sensors are demonstrated for the first time. The humidity sensing characteristics of BiOI are examined within the range of 30-80% relative humidity (RH) at an operating temperature of 323 K. The highest sensitivity level of 39 k Omega per %RH is determined for a relative humidity of 75.5%. A successful attempt is made to use this sensor as a human breathing process monitor. The sensor response times at room temperature in this test are 3.04(9) s at 0 V and 3.31(7) s at 20 V, whereas the recovery times are estimated to be 6.57(6) s at 0 V and 6.42(4) s at 20 V. Future advancements in sensing devices utilizing BiOI hold the potential to yield highly responsive, ultrafast sensors with simplified device geometries, and self-powered.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20501 - Materials engineering

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    ADVANCED MATERIALS TECHNOLOGIES

  • ISSN

    2365-709X

  • e-ISSN

    2365-709X

  • Volume of the periodical

    10

  • Issue of the periodical within the volume

    9

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    12

  • Pages from-to

    "Article number: 2401988"

  • UT code for WoS article

    001403488000001

  • EID of the result in the Scopus database

    2-s2.0-85216127734