Uncertainty of the estimation of Am 241 content in human body
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F63108089%3A_____%2F00%3A00005042" target="_blank" >RIV/63108089:_____/00:00005042 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Uncertainty of the estimation of Am 241 content in human body
Original language description
The uncertainty of the activity of Am 241 estimation when measured in vivo with special HPGe detectors for measurements of low-energy gamma radiation was estimated. All sources of uncertainty were included - couting statistics, calibration with skull phantom, unhomogenous distribution of Am 241 in skeleton. Overall uncertainly is given by factor 1.5.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
FM - Hygiene
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/NJ4965" target="_blank" >NJ4965: Study of the biokinetics of some bone-seeling radionuclides in the human organism</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2000
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Radiation Protection Dosimetry - In vivo monitoring for internal contamination: New techniques for new needs
ISBN
1-870965-66-3
ISSN
—
e-ISSN
—
Number of pages
5
Pages from-to
295-299
Publisher name
Nuclear Technology Publ.
Place of publication
London
Event location
Mol
Event date
May 21, 1999
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—