All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Radiofrequency tissue ablation inside of metal stent - A thermographic study

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F14%3A00061463" target="_blank" >RIV/65269705:_____/14:00061463 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.irbm.2014.02.007" target="_blank" >http://dx.doi.org/10.1016/j.irbm.2014.02.007</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.irbm.2014.02.007" target="_blank" >10.1016/j.irbm.2014.02.007</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Radiofrequency tissue ablation inside of metal stent - A thermographic study

  • Original language description

    Biliary stents are used to treat obstructions that occur in the bile ducts. The stents can be blocked by new tissue in a few months after their implanting. This complication can be solved by using radiofrequency ablation. The present article deals with monitoring of the process of monopolar thermoablation of a metal stent by using an infrared camera ex vivo. The metallic EGIS Biliary stents 10 mm x 80 mm were used in experiments; radiofrequency ablation due by catheter EndoHPB 8F at 460 kHz was used. The Flir B200 thermocamera was used for monitoring. The results show an increase in temperature of the stent's material during thermoablation process. It is believed that the metal stent becomes an active electrode. The results show an increase in temperature of the stent and the surrounding tissue during the treatment. Temperature distribution measured on stent was affected by power applied and obviously non-homogeneous. The maximum temperature values were observed at the ends of the sten

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FP - Other medical fields

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    IRBM

  • ISSN

    1959-0318

  • e-ISSN

  • Volume of the periodical

    35

  • Issue of the periodical within the volume

    3

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    6

  • Pages from-to

    164-169

  • UT code for WoS article

    000339412400007

  • EID of the result in the Scopus database