0/1-Hour Triage Algorithm for Myocardial Infarction in Patients With Renal Dysfunction
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F18%3A00068782" target="_blank" >RIV/65269705:_____/18:00068782 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/18:00103658
Result on the web
<a href="https://www.ahajournals.org/doi/pdf/10.1161/CIRCULATIONAHA.117.028901" target="_blank" >https://www.ahajournals.org/doi/pdf/10.1161/CIRCULATIONAHA.117.028901</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1161/CIRCULATIONAHA.117.028901" target="_blank" >10.1161/CIRCULATIONAHA.117.028901</a>
Alternative languages
Result language
angličtina
Original language name
0/1-Hour Triage Algorithm for Myocardial Infarction in Patients With Renal Dysfunction
Original language description
Background: The European Society of Cardiology recommends a 0/1-hour algorithm for rapid rule-out and rule-in of non-ST-segment elevation myocardial infarction using high-sensitivity cardiac troponin (hs-cTn) concentrations irrespective of renal function. Because patients with renal dysfunction (RD) frequently present with increased hs-cTn concentrations even in the absence of non-ST-segment elevation myocardial infarction, concern has been raised regarding the performance of the 0/1-hour algorithm in RD. Methods: In a prospective multicenter diagnostic study enrolling unselected patients presenting with suspected non-ST-segment elevation myocardial infarction to the emergency department, we assessed the diagnostic performance of the European Society of Cardiology 0/1-hour algorithm using hs-cTnT and hs-cTnI in patients with RD, defined as an estimated glomerular filtration rate <60 mL/min/1.73 m(2), and compared it to patients with normal renal function. The final diagnosis was centrally adjudicated by 2 independent cardiologists using all available information, including cardiac imaging. Safety was quantified as sensitivity in the rule-out zone, accuracy as the specificity in the rule-in zone, and efficacy as the proportion of the overall cohort assigned to either rule-out or rule-in based on the 0- and 1-hour sample. Results: Among 3254 patients, RD was present in 487 patients (15%). The prevalence of non-ST-segment elevation myocardial infarction was substantially higher in patients with RD compared with patients with normal renal function (31% versus 13%, P<0.001). Using hs-cTnT, patients with RD had comparable sensitivity of rule-out (100.0% [95% confidence interval {CI}, 97.6-100.0] versus 99.2% [95% CI, 97.6-99.8]; P=0.559), lower specificity of rule-in (88.7% [95% CI, 84.8-91.9] versus 96.5% [95% CI, 95.7-97.2]; P<0.001), and lower overall efficacy (51% versus 81%, P<0.001), mainly driven by a much lower percentage of patients eligible for rule-out (18% versus 68%, P<0.001) compared with patients with normal renal function. Using hs-cTnI, patients with RD had comparable sensitivity of rule-out (98.6% [95% CI, 95.0-99.8] versus 98.5% [95% CI, 96.5-99.5]; P=1.0), lower specificity of rule-in (84.4% [95% CI, 79.9-88.3] versus 91.7% [95% CI, 90.5-92.9]; P<0.001), and lower overall efficacy (54% versus 76%, P<0.001; proportion ruled out, 18% versus 58%, P<0.001) compared with patients with normal renal function. Conclusions: In patients with RD, the safety of the European Society of Cardiology 0/1-hour algorithm is high, but specificity of rule-in and overall efficacy are decreased. Modifications of the rule-in and rule-out thresholds did not improve the safety or overall efficacy of the 0/1-hour algorithm. Clinical Trial Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00470587.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Circulation
ISSN
0009-7322
e-ISSN
—
Volume of the periodical
137
Issue of the periodical within the volume
5
Country of publishing house
US - UNITED STATES
Number of pages
16
Pages from-to
436-451