Comparison of fourteen rule-out strategies for acute myocardial infarction
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F19%3A00070523" target="_blank" >RIV/65269705:_____/19:00070523 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/19:00109666
Result on the web
<a href="https://www.sciencedirect.com/science/article/pii/S0167527318347843?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0167527318347843?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijcard.2018.11.140" target="_blank" >10.1016/j.ijcard.2018.11.140</a>
Alternative languages
Result language
angličtina
Original language name
Comparison of fourteen rule-out strategies for acute myocardial infarction
Original language description
Background: The clinical availability of high-sensitivity cardiac troponin (hs-cTn) has enabled the development of several innovative strategies for the rapid rule-out of acute myocardial infarction (AMI). Due to the lack of direct comparisons, selection of the best strategy for clinical practice is challenging. Methods: In a prospective international multicenter diagnostic study enrolling 3696 patients presenting with suspected AMI to the emergency department, we compared the safety and efficacy of 14 different hs-cTn-based strategies: hs-cTn concentrations below the limit of detection (LoD), dual-marker combining hs-cTn with copeptin, ESC 0 h/1 h-algorithm, 0 h/2 h-algorithm, 2 h-ADP-algorithm, NICE-algorithm, and ESC 0 h/3 h-algorithm, each using either hs-cTnT or hs-cTnI. The final diagnosis of AMI was adjudicated by two independent cardiologists using all available clinical information including cardiac imaging and serial hs-cTn concentrations. Results: AMI was the final diagnosis in 16% of patients. Using hs-cTnT, safety quantified by the negative predictive value (NPV) and sensitivity was very high (99.8-100% and 99.5-100%) and comparable for all strategies, except the dual-marker approach (NPV 98.7%, sensitivity 96.7%). Similarly, using hs-cTnI, safety quantified by the NPV and sensitivity was very high (99.7-100% and 98.9-100%) and comparable for all strategies, except the dual-marker approach (NPV 96.9%, sensitivity 90.4%) and the NICE-algorithm (NPV 99.1%, sensitivity 94.7%). Efficacy, quantified by the percentage of patients eligible for rule-out, differed markedly, and was lowest for LoD-algorithm (15.7-26.8%). Conclusion: All rapid rule-out algorithms, except the dual-marker strategy and the NICE-algorithm using hs-cTnI, favorably combine safety and efficacy, and can be considered for routine clinical practice. Clinical trial registration: NCT00470587, http://clinicaltrials.gov/show/NCT00470587. (c) 2018 Elsevier B.V. All rights reserved.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
International Journal of Cardiology
ISSN
0167-5273
e-ISSN
—
Volume of the periodical
283
Issue of the periodical within the volume
MAY 15
Country of publishing house
IE - IRELAND
Number of pages
7
Pages from-to
41-47
UT code for WoS article
000461330100007