The titanium-made growth-guidance technique for early-onset scoliosis at minimum 2-year follow-up: A prospective multicenter study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F19%3A00071196" target="_blank" >RIV/65269705:_____/19:00071196 - isvavai.cz</a>
Result on the web
<a href="http://www.advances.umed.wroc.pl/pdf/2019/28/8/1073.pdf" target="_blank" >http://www.advances.umed.wroc.pl/pdf/2019/28/8/1073.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.17219/acem/102269" target="_blank" >10.17219/acem/102269</a>
Alternative languages
Result language
angličtina
Original language name
The titanium-made growth-guidance technique for early-onset scoliosis at minimum 2-year follow-up: A prospective multicenter study
Original language description
BACKGROUND: The management of early-onset scoliosis (EOS) remains a serious challenge in pediatric orthopedics. The growth-guidance system (GGS) is a surgical option that allows continuous growth along a rod, averting the need for repeated operative lengthening. OBJECTIVES: The objective of this study was to evaluate the outcomes of the GGS in the treatment of EOS. MATERIAL AND METHODS: A prospective study, including 81 patients from 4 departments treated with this method from 2013 to 2015, was conducted with a minimum follow-up period of 24 months. The follow-up data of 57 patients was available, thus the drop-out rate was 29.63%. There were 44 girls with a mean age of 10.03 years and 13 boys with a mean age of 8.04 years. RESULTS: The mean preoperative Cobb angle was 65.3o (range 36o-139o) was corrected to 23.7o (2o-94o), and at the end of the 2-year follow-up increased to 30.7o (8o-93o). The predominant proximal level of instrumentation was T5 and the distal was L1. The combined length of T1-T12 and T12-S1 increased on average by 33.19 mm in 24 months. The overall rate of serious complications was 43.86%. The most prevalent device-related complications were: the dislodgement of top screws because of the short length of the rod (14 cases), the implant failure (11 cases) and loss of correction (9 cases). CONCLUSIONS: The results show that the GGS used in this study allows for a good and stable correction while preserving the ability of the spine to grow in at least a 2-year follow-up. The complication rate is acceptable and comparable with other growth-friendly techniques. To date, this is the largest successful study on the use of titanium-made GGSs.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30211 - Orthopaedics
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Advances in Clinical and Experimental Medicine
ISSN
1899-5276
e-ISSN
—
Volume of the periodical
28
Issue of the periodical within the volume
8
Country of publishing house
PL - POLAND
Number of pages
5
Pages from-to
1073-1077
UT code for WoS article
000484049900010
EID of the result in the Scopus database
2-s2.0-85071787438