Calibration and Testing of Laboratory Electrolyser with Spouted Bed Cathode.
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F02%3A27020320" target="_blank" >RIV/67985858:_____/02:27020320 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Calibration and Testing of Laboratory Electrolyser with Spouted Bed Cathode.
Original language description
The electrowinning cell for metal deposition has been design, manufactured and tested. The laboratory size cell enable to be operated as a conventional electrolyser with slab-slab electrodes as well as un- or divided electrolyser with 3D cathode and variable thickness of cathode compartment. The calibration measurements are comparisons among various arrangements of the cell with respect to operation variables as temperature, electrolyte composition, current density, particle size and kind of separator.The copper deposition was used as a model system.
Czech name
—
Czech description
—
Classification
Type
V<sub>x</sub> - Unclassified - Research report containing classified information
CEP classification
CI - Industrial chemistry and chemical engineering
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2002
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Number of pages
18
Place of publication
Prague
Publisher/client name
Institute of Chemical Process Fundamentals AS CR
Version
—