Control Method for DC-Link Voltage Ripple Cancellation in Voltage Source Inverter under Unbalanced Three-Phase Voltage Supply Conditions.
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985866%3A_____%2F03%3A10033056" target="_blank" >RIV/67985866:_____/03:10033056 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Control Method for DC-Link Voltage Ripple Cancellation in Voltage Source Inverter under Unbalanced Three-Phase Voltage Supply Conditions.
Original language description
A control method for the compensation of unbalanced voltage supply that eliminates pulsating current in the DC bus of a voltage source inverter is investigated and analyzed. Such a pulsating current can have detrimental effects on operating properties ofthe drive as well as on the quality of power supply in the electrical vicinity of the inverter.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
JA - Electronics and optoelectronics
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GA102%2F02%2F0554" target="_blank" >GA102/02/0554: Elimination of effects of unbalanced power supply on operation of drive with solid-state converter</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2003
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
2003 IEEE International Electric Machines and Drives Conference (IEMDC).
ISBN
0-7803-7818-0
ISSN
—
e-ISSN
—
Number of pages
7
Pages from-to
869-875
Publisher name
IEEE Service Center
Place of publication
Piscataway, NJ
Event location
Madison, Wisconsin [US]
Event date
Jun 1, 2003
Type of event by nationality
WRD - Celosvětová akce