Comparison of electrorheological measurements based on different methods of electric field generation

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985874%3A_____%2F14%3A00427857" target="_blank" >RIV/67985874:_____/14:00427857 - isvavai.cz</a>

  • Alternative codes found

    RIV/70883521:28610/14:43871801

  • Result on the web

    <a href="http://dx.doi.org/10.3933/ApplRheol-24-42875" target="_blank" >http://dx.doi.org/10.3933/ApplRheol-24-42875</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3933/ApplRheol-24-42875" target="_blank" >10.3933/ApplRheol-24-42875</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Comparison of electrorheological measurements based on different methods of electric field generation

  • Original language description

    Electrorheological measurements represent a key approach in characterizing the efficiency of electrorheological fluids. The rotational rheometers, the Physica MCR 501 (Anton Paar) equipped with an electrorheological cell and the Bohlin Gemini CVOR 150 (Malvern Instruments) modified for electrorheological experiments generate an electric field in two completely different ways. Each of the two generations has a specific influence on electrorheological measurements. The experimental data were obtained andcompared for a suspension of polyaniline powders mixed (10 wt%) in silicone oil. For a concentric-cylinders arrangement, it was shown that the data are fully comparable for both rheometers. However, for a parallel-plate arrangement, the data using the Physica MCR 501 provide higher values in comparison with both the corresponding plate-plate data obtained with the Bohlin Gemini CVOR 150 and with the mutually comparable concentric cylinders data.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    BK - Liquid mechanics

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/GAP105%2F11%2F2342" target="_blank" >GAP105/11/2342: Usage of electrorheological measurements in predictability of the process of electrospinning</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Applied Rheology

  • ISSN

    1430-6395

  • e-ISSN

  • Volume of the periodical

    24

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    4

  • Pages from-to

    42875-1-42875-4

  • UT code for WoS article

    000342886700005

  • EID of the result in the Scopus database