All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Poly(luminol) based sensor array for determination of dissolved chlorine in water

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985882%3A_____%2F14%3A00428554" target="_blank" >RIV/67985882:_____/14:00428554 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.snb.2013.10.080" target="_blank" >http://dx.doi.org/10.1016/j.snb.2013.10.080</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.snb.2013.10.080" target="_blank" >10.1016/j.snb.2013.10.080</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Poly(luminol) based sensor array for determination of dissolved chlorine in water

  • Original language description

    An optical sensor for determination of free chlorine content of drinking water was prepared and tested. The function of the sensor is based on detecting chemiluminescence signal provided by thin immobilized poly(luminol) reagent layer. The poly(luminol)reagent film was prepared by electropolymerization of luminol onto planar indium-tin-oxide (ITO) electrode. Different methods, like electrode potential cyclization (cyclic voltammetry, CV), pulsed potential electrolysis (pulsed amperometry, PA) and potentiostatic electrolysis (constant potential electrolysis, PSE) were employed for preparation of the poly(luminol) layer. The chemoluminescence (chemiluminescence) of the differently prepared films was investigated in the poly(luminol) - hypochlorite - hydrogen peroxide reaction. Highest luminescence signal was obtained by the films prepared with CV. Poly(luminol) layers deposited with pulsed potential showed 80% less luminescence while almost no signal was obtained in case of films made w

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    JA - Electronics and optoelectronics

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Sensors and Actuators B - Chemical

  • ISSN

    0925-4005

  • e-ISSN

  • Volume of the periodical

  • Issue of the periodical within the volume

    192

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    7

  • Pages from-to

    92-98

  • UT code for WoS article

    000329167500014

  • EID of the result in the Scopus database