Instrumented pig gait analysis: State-of-the-art
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985904%3A_____%2F21%3A00548623" target="_blank" >RIV/67985904:_____/21:00548623 - isvavai.cz</a>
Alternative codes found
RIV/68407700:21460/21:00351345
Result on the web
<a href="https://asep.lib.cas.cz/arl-cav/cs/csg/?repo=crepo1&key=14918212361" target="_blank" >https://asep.lib.cas.cz/arl-cav/cs/csg/?repo=crepo1&key=14918212361</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jveb.2021.06.006" target="_blank" >10.1016/j.jveb.2021.06.006</a>
Alternative languages
Result language
angličtina
Original language name
Instrumented pig gait analysis: State-of-the-art
Original language description
There are 2 main reasons why pig gait is analysed. First, assessment of a pig's health and welfare is major reason for gait analysis. Also, the pig, as a large animal model, has become important in biomedical research, especially in preclinical testing of therapeutics. Gait is an essential part of pig movement and its analysis is of great interest, especially when following the phenotype and the effectivity of treatment in pig models for movement and neurological disorders. The aim of this state-of-the-art review is 3-fold: (1) to present and summarize the current instrument base used in pig gait assessment, (2) to point out promising technologies for pig gait analysis, and (3) to outline the suitability of technology for pig gait analysis. The review encompasses 27 studies in total. We included papers published since 2010 and classified them according to which type of measurement instrument was used: 2D camera systems, 3D camera systems, force plates and pressure sensitive mats. In each category we reviewed the data acquisition systems, utilized signals and gait parameters used. An analysis of the literature showed that video-based systems and pressure sensitive mats were the most frequently used. The utilization of 3D camera systems was less common. Force plates were only used occasionally. In conclusion, despite growing interest in using inertial sensor units in movement analysis, they were missing in pig gait analysis. Along with the progress in instrumentation and its ability to produce a huge amount of information, simpler and more user-friendly tools should be developed to provide easy interpretation of the data captured by pig practitioners in the pig industry, or by scientists.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10614 - Behavioral sciences biology
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Veterinary Behavior-Clinical Applications and Research
ISSN
1558-7878
e-ISSN
1878-7517
Volume of the periodical
45
Issue of the periodical within the volume
Sept - Oct 2021
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
9
Pages from-to
51-59
UT code for WoS article
000703714300008
EID of the result in the Scopus database
2-s2.0-85114304251