Role of orthoptics and scoring system for orbital floor blowout fracture: surgical or conservative treatment
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985904%3A_____%2F21%3A00551025" target="_blank" >RIV/67985904:_____/21:00551025 - isvavai.cz</a>
Alternative codes found
RIV/00843989:_____/21:E0109263 RIV/61988987:17110/21:A2302GB2
Result on the web
<a href="http://ies.ijo.cn/gjyken/ch/reader/view_abstract.aspx?file_no=20211218&flag=1" target="_blank" >http://ies.ijo.cn/gjyken/ch/reader/view_abstract.aspx?file_no=20211218&flag=1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.18240/ijo.2021.12.18" target="_blank" >10.18240/ijo.2021.12.18</a>
Alternative languages
Result language
angličtina
Original language name
Role of orthoptics and scoring system for orbital floor blowout fracture: surgical or conservative treatment
Original language description
AIM: To assess the role of orthoptics in referring patients with orbital floor blowout fracture (OFBF) for conservative or surgical treatment and based on the results, to propose a scoring system for such decision making.nnMETHODS: A retrospective analysis of 69 patients with OFBF was performed (35 treated conservatively, 34 surgically). The role of orthoptics in referring to surgery or conservative treatment was retrospectively evaluated, the factors with the highest significance for decision making were identified, and a scoring system proposed using Logistic regression.nnRESULTS: According to defined criteria, the treatment was unsuccessful in 2 (6%) surgically treated and only in one (3%) conservatively treated patient. The proposed scoring system includes the defect size and several values resulting from the orthoptic examination, the elevation of the eyebulb measured on Lancaster screen being the most significant.nnCONCLUSION: The study demonstrates the benefits of orthoptic examination when making decisions on conservative or surgical treatment and for diagnosing ocular motility disorder (with or without binocular diplopia) in OFBF patients. The proposed scoring system could, following verification in a prospective study, become a valuable adjunctive tool.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30206 - Otorhinolaryngology
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Ophthalmology-IJO
ISSN
2222-3959
e-ISSN
2227-4898
Volume of the periodical
14
Issue of the periodical within the volume
12
Country of publishing house
CN - CHINA
Number of pages
7
Pages from-to
1928-1934
UT code for WoS article
000727304900018
EID of the result in the Scopus database
2-s2.0-85120977871