Electrodeposition of Silver Amalgam on Thin Gold Film Electrodes for Voltammetric Detection of 4-Nitrophenol and DNA Labeled with Osmium Tetroxide-Bipyridine Complex
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081707%3A_____%2F19%3A00518368" target="_blank" >RIV/68081707:_____/19:00518368 - isvavai.cz</a>
Alternative codes found
RIV/00216305:26620/19:PU134306
Result on the web
<a href="http://dspace.lib.vutbr.cz/xmlui/bitstream/11012/184643/1/2019%20Electroanalsis%20Havranova%20Preprint.pdf" target="_blank" >http://dspace.lib.vutbr.cz/xmlui/bitstream/11012/184643/1/2019%20Electroanalsis%20Havranova%20Preprint.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201900306" target="_blank" >10.1002/elan.201900306</a>
Alternative languages
Result language
angličtina
Original language name
Electrodeposition of Silver Amalgam on Thin Gold Film Electrodes for Voltammetric Detection of 4-Nitrophenol and DNA Labeled with Osmium Tetroxide-Bipyridine Complex
Original language description
Alternative electrode materials suitable to prepare novel working electrode applicable in detecting biopolymers such as nucleic acids, proteins or glycoproteins, represent a significant contribution to bio-electroanalysis. Herein, electrodes made of vapor-deposited thin gold films (vAuE) were used as an alternative substrate for the electrodeposition of silver amalgam particles (AgAPs), next to indium tin oxide and pyrolytic graphite, which are already used. The conditions and parameters of double pulse chronoamperometry were optimized for the most-sensitive voltammetric detection of 4-nitrophenol (4-NP). The resulting electrodes were characterized by scanning electron microscope with energy dispersive X-ray spectroscopy. While 4-NP could not be detected by bare nonactivated vAuEs at all, their electrochemical activation offered a limit of detection (LoD) of 25 and 5 mu mol.l(-1) by means of CV and DPV, respectively. AgAP electrodeposited on vAuE, offered 2.5-times lower LoDs 10 mu mol.l(-1) by CV and comparable LoD 5 mu mol.l(-1) by DPV. Advantageously, AgAPs could be repeatedly deposited on and anodically dissolved from the vAuE with a relative standard deviation 13 % of the ten-times repeated DPV signal of 4-NP (100 mu mol.l(-1)). In comparison to vAuE, the vAuE-AgAP offered about 400 mV broader potential window, which allowed detection of single strand DNA fragment labeled by osmium tetroxide-bipyridine complex down to 2 ng.mu l(-1) by means of DPV.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Volume of the periodical
31
Issue of the periodical within the volume
10
Country of publishing house
DE - GERMANY
Number of pages
9
Pages from-to
1952-1960
UT code for WoS article
000474183900001