Trapping of stibine on a molybdenum foil strip
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F04%3A00102253" target="_blank" >RIV/68081715:_____/04:00102253 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Trapping of stibine on a molybdenum foil strip
Original language description
A prototype of a miniature collection device based on a molybdenum strip combined with miniature hydrogen diffusion flame was designed and a complementary study of trapping antimony hydride on the molybdenum strip was performed to that dealing with arsenic and selenium hydrides. Influence of trapping temperature, surface modification with noble metals - Ir, Pt, Rh, argon carrier gas flow rate, distance between the orifice of the injection capillary and the strip, sample volume and composition of the gaseous phase (argon-hydrogen) was investigated by atomic absorption spectrometry. In addition, analytical figures of merit (LOD, LOQ) were estimated. In contrast to As and Se, antimony was trapped efficiently only with bare molybdenum surface. Absence of hydrogen in the gaseous phase during antimony trapping does not play decisive role
Czech name
Záchyt stibanu na pásku molybdenové folie
Czech description
Byl navržen prototyp miniaturního kolekčního zařízení na bázi molybdenového pásku kombinovaného s miniaturním vodíkovým difúzním plamínkem. Byla uskutečněna komplementární studie chování antimonu ke zkoumání chování arsenu a selenu na tomto zařízení.S využitím atomové absorpční spektrometrie byl zkoumán vliv teploty záchytu, modifikace povrchu molybdenu Ir, Pr, Rh, průtoku nosného plynu, vzdálenosti otvoru injekční kapiláry od povrchu pásku, objemu vzorku a složení plynné fáze (argon-vodík). Dále byly odhadnuty důležité analytické parametry (mez detekce a mez kvantifikace) této techniky. Oproti As a Se byl antimon účinně zachycován jen holým, nemodifikovaným povrchem molybdenu. Absence vodíku v plynné fázi během záchytu nehraje podstatnou roli pro účinnost kolekce
Classification
Type
D - Article in proceedings
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GA203%2F01%2F0453" target="_blank" >GA203/01/0453: Development of promising techniques of generation and atomization of volatile compounds for ultratrace element analysis and for speciation by atomic spectrometr</a><br>
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2004
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
6th European Furnace Symposium and 11th Solid Sampling Colloquium with Atomic Spectrometry
ISBN
963-9319-38-4
ISSN
—
e-ISSN
—
Number of pages
1
Pages from-to