All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Bridged polysilsesquioxane-based wide-bore monolithic capillary columns for hydrophilic interaction chromatography

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F17%3A00469740" target="_blank" >RIV/68081715:_____/17:00469740 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.chroma.2016.11.062" target="_blank" >http://dx.doi.org/10.1016/j.chroma.2016.11.062</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.chroma.2016.11.062" target="_blank" >10.1016/j.chroma.2016.11.062</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Bridged polysilsesquioxane-based wide-bore monolithic capillary columns for hydrophilic interaction chromatography

  • Original language description

    The synthesis and characterization of large-bore silica-based monolithic capillary columns (0.32 mm × 150 mm) are presented. Columns were prepared by acidic hydrolysis of a mixture containing tetramethoxysilane (TMOS) and 1,2-bis(trimethoxysilyl)ethane (BTME) in different molar ratios in the presence of polyethylene glycol and urea. The monoliths were modified by zwitterionic monomer [2-(methacryloyloxy)ethyl]-dimethyl-(3-sulfopropyl)-ammonium hydroxide via 3-(trimethoxysilyl)propyl methacrylate. Prepared stationary phases were evaluated by scanning electron microscopy and chromatographic separation of nucleobases and their derivatives in the HILIC mode. The best chromatographic results were obtained with the column prepared from the reaction mixture containing BTME and TMOS in a 1:4 molar ratio. The permeability of such column reached 1.68 × 10−14 m2 and the efficiency, expressed as a height equivalent of the theoretical plate, did not exceed 10.5 μm for the tested compounds. The columns were successfully applied to HILIC separation of native and labeled oligosaccharides and glycans released from bovine ribonuclease B and human immunoglobulin G.

  • Czech name

    —

  • Czech description

    —

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

    —

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Chromatography A

  • ISSN

    0021-9673

  • e-ISSN

    —

  • Volume of the periodical

    1479

  • Issue of the periodical within the volume

    JAN

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    6

  • Pages from-to

    204-209

  • UT code for WoS article

    000392681300023

  • EID of the result in the Scopus database

    2-s2.0-85008244059