All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

The Application of Miniaturized Three-Point-Bend Specimens for Determination of the Reference Temperature of A533 Cl.1 Steel

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081723%3A_____%2F17%3A00481466" target="_blank" >RIV/68081723:_____/17:00481466 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1115/1.4036532" target="_blank" >http://dx.doi.org/10.1115/1.4036532</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1115/1.4036532" target="_blank" >10.1115/1.4036532</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    The Application of Miniaturized Three-Point-Bend Specimens for Determination of the Reference Temperature of A533 Cl.1 Steel

  • Original language description

    This contribution deals with the determination of the reference temperature of JRQ steel using miniaturizednspecimens. The dimensions of the miniaturized specimens used were 3 × 4 × 27 mm (thickness × width ×nlength). This specimen type allows utilizing a limited amount of test material or the broken halves of pre-crackednCharpy or larger specimens. The test material comes from the broken halves of 0.5T SE(B) specimensnpreviously tested for the determination of the reference temperature at Ciemat, Madrid. The fracture toughnessntests were performed in the transition region of the steel according to the recommendations of the standardnASTM E1921 and according to Wallin’s recommended temperature range of miniaturized specimens. Thenreference temperature of the Master Curve was very similar to the ones obtained from three-point-bendnspecimens of sizes 0.2T, 0.4T and 0.5T. The results obtained confirm a necessity to conduct tests at lowntemperatures and to test a sufficient number of specimens in order to generate enough valid data for thendetermination of the reference temperature.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20306 - Audio engineering, reliability analysis

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Pressure Vessel Technology-Transactions of the Asme

  • ISSN

    0094-9930

  • e-ISSN

  • Volume of the periodical

    139

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    6

  • Pages from-to

  • UT code for WoS article

    000403902100022

  • EID of the result in the Scopus database

    2-s2.0-85019699188