Thermal radiative properties of a DLC coating
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F08%3A00314213" target="_blank" >RIV/68081731:_____/08:00314213 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Thermal radiative properties of a DLC coating
Original language description
Thermal radiative properties of a DLC coating were measured in the range of cryogenic and room temperatures. Both the total hemispherical emissivity and absorptivity are significantly dependent on the radiation temperature and change from the value of 0.032 at 15 K to 0.65 at 300 K.
Czech name
Tepelně radiační vlastnosti povlaku DLC
Czech description
Na plochých vzorcích o průměru 40 mm byly měřeny tepelně radiační vlastnosti (emisivita a absorptivita) povlaku DLC (Diamond-Like-Carbon) v rozsahu od kryogenních teplot až po teplotu pokojovou. Ke stanovení radiačního tepelného toku mezi vzorky se použilo teplotního spádu na kalibrovaném tepelném odporu. Jak totální hemisférická emisivita, tak i absorptivita významně závisejí na teplotě záření a mění se od hodnoty 0.032 při 15 K do 0.65 K při 300 K.
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
BJ - Thermodynamics
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2008
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Cryogenics
ISSN
0011-2275
e-ISSN
—
Volume of the periodical
48
Issue of the periodical within the volume
9-10
Country of publishing house
GB - UNITED KINGDOM
Number of pages
3
Pages from-to
—
UT code for WoS article
000259430300009
EID of the result in the Scopus database
—