Measurement of Pulse Wave Velocity during Valsalva and Mueller Maneuvers by Whole Body Impedance Monitor
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F14%3A00437710" target="_blank" >RIV/68081731:_____/14:00437710 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Measurement of Pulse Wave Velocity during Valsalva and Mueller Maneuvers by Whole Body Impedance Monitor
Original language description
Elevated arterial stiffness is a marker of vascular aging and is connected with increased mortality. Noninvasive measurement of arterial stiffness is based on the measurement of pulse wave velocity (PWV), where PWV correlates with arterial stiffness. PWV depends on blood pressure and other physiological conditions. The aim of our study was to measure and analyze the effect of changes in airway pressure to PWVs between the chest and limbs. Valsalva and Mueller maneuvers and spontaneous breathing were used. We measured 30 healthy, non-smoking subjects aged between 21 and 35 years. Simultaneous measurements of whole body impedance, blood pressure and ECG were taken in a supine position. The relative changes in PWV values (mean ± standard deviation) during the Valsalva maneuver were: 0.82 ± 0.11 (thigh) 0.87 ± 0.10 (calf) 0.64 ± 0.19 (arm) 0.75 ± 0.16 (forearm) during the Mueller maneuver they were: 0.92 ± 0.11 (thigh) 0.91 ± 0.09 (calf) 0.76 ± 0.19 (arm) 0.81 ± 0.14 (forearm). PWVs were lower during maneuvers than during spontaneous breathing. Changes in PWV during breathing maneuvers were more reflected nearer to the chest. Our results show PWV reference values between various parts of the human body during changes in airway pressure demonstrated by the Valsalva and Mueller maneuvers.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20601 - Medical engineering
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Computing in Cardiology 2014
ISBN
978-1-4799-4346-3
ISSN
—
e-ISSN
—
Number of pages
4
Pages from-to
557-560
Publisher name
Computing in Cardiology
Place of publication
Cambridge
Event location
Cambridge
Event date
Sep 7, 2014
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
000370068300281