For a correct assessment of stereo-electroencephalographic (SEEG) recordings, a proper signal electrical reference is necessary. Such a reference might be physical or virtual. Physical reference can be noisy and a proper virtual reference calculation is often time-consuming. This paper uses the variance of the SEEG signals to calculate the reference from relatively low noise signals to reduce the contamination by distant sources, while maintaining negligible computing time.Ten patients with SEEG recordings were used in this study. 20-second long recordings from each patient, sampled at 5000 Hz, were used to calculate variances of SEEG signals and a low-variance (LV) subset of signals was selected for each patient. Consequently, 4 different reference signals were calculated using: 1) an average signal from WM contacts only (AVG_WM), 2) an average signal from LV contacts only (AVG_LV), 3) independent component analysis (ICA) method from WM contacts only (ICA_WM), and 4) ICA method from LV signals only (ICA_LV). Also, the original testing reference, an average signal from all SEEG contacts (AVG) was utilized. Finally, bipolar signals and average signals from anatomical structures were calculated and used to evaluate reference signals.91.7% of the WM SEEG contacts were found below the average variance. ICA_LV showed the best and AVG_WM the worst overall results. AVG_LV had the most positive impact on minimizing the mutual correlations between separate brain structures and correcting the outliers. The average processing time for ICA methods was 66.72 seconds and 0.7870 seconds for AVG methods (100 000 samples, 125.7±20.4 SEEG signals).Utilizing the LV data subset improves the reference signal. WM references are difficult to obtain and seem to be more susceptible to errors caused by low number of WM contacts in the dataset. ICA_LV can be considered as one of the best reference estimations, however the calculation is very demanding and time consuming. AVG_LV shows good and stable results, while it is based on a straightforward methodology and outstandingly fast calculation.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20601 - Medical engineering
Result continuities
Project
<a href="/en/project/LTAUSA18056" target="_blank" >LTAUSA18056: Seizure onset zone localization and advanced analysis of high-frequency intracranial EEG</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC)
ISBN
978-1-7281-1990-8
ISSN
1557-170X
e-ISSN
—
Number of pages
4
Pages from-to
(2020)
Publisher name
IEEE
Place of publication
New York
Event location
Montreal
Event date
Jul 20, 2020
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
000621592200050