Methinium colorimetric sensors for the determination of cholesterol sulfate in an aqueous medium
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378050%3A_____%2F17%3A00507410" target="_blank" >RIV/68378050:_____/17:00507410 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11110/17:10362281 RIV/00064165:_____/17:10362281 RIV/60461373:22340/17:43913253
Result on the web
<a href="https://www.sciencedirect.com/science/article/abs/pii/S0925400517301909?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S0925400517301909?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.snb.2017.01.185" target="_blank" >10.1016/j.snb.2017.01.185</a>
Alternative languages
Result language
angličtina
Original language name
Methinium colorimetric sensors for the determination of cholesterol sulfate in an aqueous medium
Original language description
Methinium colorimetric sensors 1 and 2 were studied for the determination of cholesterol sulfate by UV-Vis spectroscopy in 0.001 M NaCl (H2O:MeOH, 7:3), pH = 7.34. Both of the tested sensors displayed high affinity, excellent selectivity and sensitivity for cholesterol sulfate against other steroids (estrone sulfate, pregnenolone sulfate, cholesterol, cholic acid and taurocholic acid). The determined values of conditional binding constants, linear ranges and detection limits demonstrated the high usability of these sensors for the determination of cholesterol sulfate. For example, the detection limits of tested sensors I and 2 for the detection of cholesterol sulfate were 0.16 mu M (0.07 mg/L, R-2 = 0.9966) and 1.3 mu M (0.59 mg/L, R-2 = 0.9872), respectively. Our detection limit strongly indicates the potential usability of these sensors for the determination of biologically important levels of cholesterol sulfate. (C) 2017 Elsevier B.V. All rights reserved.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10608 - Biochemistry and molecular biology
Result continuities
Project
<a href="/en/project/LQ1604" target="_blank" >LQ1604: BIOCEV: from Fundamental to Applied Research</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Sensors and Actuators B - Chemical
ISSN
0925-4005
e-ISSN
—
Volume of the periodical
245
Issue of the periodical within the volume
June
Country of publishing house
CH - SWITZERLAND
Number of pages
7
Pages from-to
1032-1038
UT code for WoS article
000398760700121