Study on the gain and photon detection efficiency drops of silicon photomultipliers under bright background conditions
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A90247%2F24%3A00643328" target="_blank" >RIV/68378271:90247/24:00643328 - isvavai.cz</a>
Result on the web
<a href="https://pos.sissa.it/444/674/pdf" target="_blank" >https://pos.sissa.it/444/674/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.22323/1.444.0674" target="_blank" >10.22323/1.444.0674</a>
Alternative languages
Result language
angličtina
Original language name
Study on the gain and photon detection efficiency drops of silicon photomultipliers under bright background conditions
Original language description
The use of silicon photomultipliers (SiPMs) in imaging atmospheric Cherenkov telescopes is expected to extend the observation times of very-high-energy gamma-ray sources, particularly within the highest energy domain of 50–300 TeV, where the Cherenkov signal from celestial gamma rays is adequate even under bright moonlight background conditions. Unlike conventional photomultiplier tubes, SiPMs do not exhibit quantum efficiency or gain degradation, which can be observed after long exposures to bright illumination. However, under bright conditions, the photon detection efficiency of a SiPM can be undergo temporary degradation because a fraction of its avalanche photodiode cells can saturate owing to photons from the night-sky background (NSB). In addition, the large current generated by the high NSB rate can increase the temperature of the silicon substrate, resulting in shifts in the SiPM breakdown voltages and consequent gain changes. Moreover, this large current changes the effective bias voltage because it causes a voltage drop across the protection resistor of 100–1000 Ω. Hence, these three factors, namely the avalanche photodiode (APD) saturation, Si temperature, and voltage drop must be carefully compensated for and/or considered in the energy calibration of Cherenkov telescopes with SiPM cameras. In this study, we measured the signal output charge of a SiPM and its variation as a function of different NSB-like background conditions up to 1 GHz/pixel. The results verify that the product of the SiPM gain and photon detection efficiency is well characterized by these three factors.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
10303 - Particles and field physics
Result continuities
Project
—
Continuities
—
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Proceedings of Science
ISBN
—
ISSN
1824-8039
e-ISSN
—
Number of pages
8
Pages from-to
674
Publisher name
Sissa Medilab srl
Place of publication
Trieste
Event location
Nagoya
Event date
Jul 26, 2023
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—