Inspection of local wall thinning by different magnetic methods

Result description

The applicability of three different magnetic methods, Magnetic flux leakage technique (MFL), Magnetic adaptive testing and Metal memory method (MMM) was tested for detection of an artificial slot in a system of three steel plates. It was found that MAT resulted in the best signal/noise ratio, and it is capable to detect the bottom side slot even in the three layer configuration. MFL also resulted in acceptable signal/noise ratio in the two layer configuration, but it was not able to detect the slot through two other plates. MMM was not found to be suitable for unstressed and un-magnetized slot detection in the given experimental arrangement.

Keywords

pipemagnetic NDTlocal wall thinningmagnetic adaptive testingmagnetic flux leakage measurement

The result's identifiers

Alternative languages

  • Result language

    angličtina

  • Original language name

    Inspection of local wall thinning by different magnetic methods

  • Original language description

    The applicability of three different magnetic methods, Magnetic flux leakage technique (MFL), Magnetic adaptive testing and Metal memory method (MMM) was tested for detection of an artificial slot in a system of three steel plates. It was found that MAT resulted in the best signal/noise ratio, and it is capable to detect the bottom side slot even in the three layer configuration. MFL also resulted in acceptable signal/noise ratio in the two layer configuration, but it was not able to detect the slot through two other plates. MMM was not found to be suitable for unstressed and un-magnetized slot detection in the given experimental arrangement.

  • Czech name

  • Czech description

Classification

  • Type

    Jimp - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10302 - Condensed matter physics (including formerly solid state physics, supercond.)

Result continuities

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Nondestructive Evaluation

  • ISSN

    0195-9298

  • e-ISSN

  • Volume of the periodical

    37

  • Issue of the periodical within the volume

    3

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    8

  • Pages from-to

    1-8

  • UT code for WoS article

    000442050200001

  • EID of the result in the Scopus database

    2-s2.0-85052237709

Result type

Jimp - Article in a specialist periodical, which is included in the Web of Science database

Jimp

OECD FORD

Condensed matter physics (including formerly solid state physics, supercond.)

Year of implementation

2018