Initial tests of large format sensors for the ATLAS ITk strip tracker
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F21%3A00541870" target="_blank" >RIV/68378271:_____/21:00541870 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1016/j.nima.2020.164677" target="_blank" >https://doi.org/10.1016/j.nima.2020.164677</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2020.164677" target="_blank" >10.1016/j.nima.2020.164677</a>
Alternative languages
Result language
angličtina
Original language name
Initial tests of large format sensors for the ATLAS ITk strip tracker
Original language description
For the construction of the Inner Tracker (ITk) as part of the phase-II upgrade programme of the ATLAS detector or the High-Luminosity (HL) LHC, batches of Long Strip (LS) and Short Strip (SS) n+-in-p type micro-strip sensors have been produced by Hamamatsu Photonics and Infineon. The full size sensors measure approximately 98×98 mm2 and are designed and engineered for tolerance against the 9.7×1014 1 MeV neq/cm2 fluence expected at the HL-LHC, including a safety factor of 1.5. Each sensor has 2 or 4 columns of 1280 individual channels arranged at 75.5 μm horizontal pitch. To ensure the sensors comply with their specifications, a Quality Control (QC) procedure has been implemented, comprising measurements on every individual sensor as well as on a sample basis. Every sensor is subjected to an initial visual inspection, after which the full surface of the sensor is captured with very high resolution by an automated camera setup. Non-contact metrology is performed to obtain the sensor surface profile. Electrical measurements establishing the reverse bias leakage current and depletion voltage are then conducted automatically. Sample sensors from every batch are subjected to 40 h of leakage stability checks in controlled atmosphere, and tests on every channel measuring leakage current, coupling capacitance and bias resistance are done. The recorded results are uploaded to a production database following data quality checks. In this paper, QC test validation data and the compiled results for the first batches of production grade sensors are presented. The QC protocol was validated, and the first production sensors were confirmed to be within specification. The results are compared to those from the previous generation of prototype sensors.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10303 - Particles and field physics
Result continuities
Project
<a href="/en/project/LTT17018" target="_blank" >LTT17018: Getting new knowledge of the microworld using the CERN infrastructure</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Nuclear Instruments & Methods in Physics Research Section A
ISSN
0168-9002
e-ISSN
1872-9576
Volume of the periodical
986
Issue of the periodical within the volume
Jan
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
6
Pages from-to
164677
UT code for WoS article
000594622600008
EID of the result in the Scopus database
2-s2.0-85092747845