All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

The XY scanner - A versatile method of the absolute end-to-end calibration of fluorescence detectors

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F22%3A00552294" target="_blank" >RIV/68378271:_____/22:00552294 - isvavai.cz</a>

  • Alternative codes found

    RIV/61989592:15310/21:73610092 RIV/61989592:15310/22:73617368

  • Result on the web

    <a href="https://pos.sissa.it/395/220/pdf" target="_blank" >https://pos.sissa.it/395/220/pdf</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.22323/1.395.0220" target="_blank" >10.22323/1.395.0220</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    The XY scanner - A versatile method of the absolute end-to-end calibration of fluorescence detectors

  • Original language description

    One of the crucial detector systems of the Pierre Auger Observatory is the fluorescence detector composed of 27 large-aperture wide-angle Schmidt telescopes. In the past, these telescopes were absolutely calibrated by illuminating the whole aperture with a uniform large-diameter light source. This absolute calibration was performed roughly once every three years, while a relative calibration was performed on a nightly basis. In this contribution, a new technique for an absolute end-to-end calibration of the fluorescence telescopes is presented. For this technique, a portable, calibrated light source mounted on a rail system is moved across the aperture of each telescope instead of illuminating the whole aperture at once. A dedicated setup using a combination of NIST traceable photodiodes to measure the mean intensity and a PMT for pulse-to-pulse stability tracking has been built for the absolute calibration of the light source.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    10303 - Particles and field physics

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of Science

  • ISBN

  • ISSN

    1824-8039

  • e-ISSN

  • Number of pages

    12

  • Pages from-to

    220

  • Publisher name

    Sissa Medilab srl

  • Place of publication

    Trieste

  • Event location

    Berlin

  • Event date

    Jul 12, 2021

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article