Comparison of OSL and TL doseemeters with data collected at the MT25 cyclic electron accelerator
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F22%3A00566280" target="_blank" >RIV/68378271:_____/22:00566280 - isvavai.cz</a>
Alternative codes found
RIV/61389005:_____/22:00566280
Result on the web
<a href="https://doi.org/10.1093/rpd/ncac117" target="_blank" >https://doi.org/10.1093/rpd/ncac117</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncac117" target="_blank" >10.1093/rpd/ncac117</a>
Alternative languages
Result language
angličtina
Original language name
Comparison of OSL and TL doseemeters with data collected at the MT25 cyclic electron accelerator
Original language description
The Microtron MT25 is a cyclic electron accelerator with a Kapitza resonator, maximum beam energy of 25 MeV, standard repetition frequency of 423 Hz, pulse length of 3.5 mu s and mean current of 30 mu A. Studies at conventional particle accelerators allow to understand the response of dosemeters in known and controllable radiation fields. Subsequently, it is possible to develop models and predict their behavior in complex radiation fields, such as those generated at laser and FLASH facilities. Therefore, response of thermally and optically stimulated luminescence detectors outside of the beam was studied at the Microtron MT25. The detectors were placed on a Plexiglas phantom inside a lead and iron bunker to shield-off background radiation. In addition, GAFChromic (TM) films and track detectors were used. Two irradiations were performed: with and without an 8-cm thick polyethylene moderator. This paper presents a comparison of the responses of the different detection systems.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10304 - Nuclear physics
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Volume of the periodical
198
Issue of the periodical within the volume
9/10/11
Country of publishing house
GB - UNITED KINGDOM
Number of pages
5
Pages from-to
670-674
UT code for WoS article
000844405700031
EID of the result in the Scopus database
2-s2.0-85137124612