Nanosecond photoluminescence decay in Mo-doped ZnO nanorods observed by TCSPC and phase shift methods
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F24%3A00599694" target="_blank" >RIV/68378271:_____/24:00599694 - isvavai.cz</a>
Alternative codes found
RIV/68407700:21230/24:00377551
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Nanosecond photoluminescence decay in Mo-doped ZnO nanorods observed by TCSPC and phase shift methods
Original language description
Hydrothermally grown, pellet-pressed Mo-doped zinc oxide (ZnO) nanocrystals were investigated for time-resolved photoluminescence at room temperature under UV excitation. Two optical setups were compared. The TCSPC setup was based on ns-short-pulse excitation followed by time resolved histogram-like counting of emitted photons. The phase-shift method was based on the frequency-resolved phase delay between sinusoidal excitation and emission. Whereas the TCSPC method is nowadays a commercially available and widely used, the second method was built as a low-cost student’s setup with a conventional UV LED as the excitation source, sine-wave voltage generator, an old dispersive monochromator, optical band-pass and long-pass filters, a red-enhanced photomultiplier and a lock-in amplifier. Recently, the setup was upgraded by a new HF2LI Zurich Instruments 50 MHz lock-in amplifier, which also includes pulse generator and a current amplifier to measure the PMT photocurrent. Both methods gave a similar time resolution slightly below 1 ns. While the time resolution of the TCSPC was limited by the excitation pulse width, the time resolution of the phase shift method was limited by the maximum operating frequency of the UV LED (several MHz). To be able to measure the PL decay in ps range, we need to replace UV LED by a new, faster UV excitation source to increase the excitation frequency up to the 50 MHz limit of our lock-in amplifier.
Czech name
—
Czech description
—
Classification
Type
O - Miscellaneous
CEP classification
—
OECD FORD branch
10302 - Condensed matter physics (including formerly solid state physics, supercond.)
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů