High resolution X-ray micro-CT imaging of fibrin scaffold using large area single photon counting detector
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F18%3A00497929" target="_blank" >RIV/68378297:_____/18:00497929 - isvavai.cz</a>
Alternative codes found
RIV/68407700:21670/18:00329977
Result on the web
<a href="https://doi.org/10.1088/1748-0221/13/12/C12006" target="_blank" >https://doi.org/10.1088/1748-0221/13/12/C12006</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/13/12/C12006" target="_blank" >10.1088/1748-0221/13/12/C12006</a>
Alternative languages
Result language
angličtina
Original language name
High resolution X-ray micro-CT imaging of fibrin scaffold using large area single photon counting detector
Original language description
This paper deals with the high resolution X-ray micro-computed tomographical (micro-CT) visualization of a fibrin scaffold intended to be used during medical repairs of various types of human tissue. Due to the cellular nature of scaffolds, it is important to inspect their Microstructure in high detail on a volumetric basis. In this work, we demonstrate the micro-CT measurement of a fibrin-based bone scaffold performed using a proprietarily developed tomographical scanner equipped with a large-area imaging device (LAD) composed of 10 x 10 Timepix silicon pixel detectors without any gaps between the individual tiles. The fibrin scaffolds are based on organic materials, which may be reinforced by various additives to improve their mechanical characteristics, and their dimensions are generally very small (i.e. micrometer to millimeter scale). As the organic material used in fibrin scaffolds exhibits very low X-ray attenuation, low-energy X-ray radiation is desirable to achieve sufficient contrast in the projections. Moreover, a high resolution is needed to visualize the fine features in the scaffolds. Here, conventional scintillation detectors suffer two problems that make the aforementioned LAD superior for the imaging of the investigated scaffolds: a wide point-spread function and low sensitivity at low energies. Despite the high LAD sensitivity to low-energy photons, it was necessary to apply several correction procedures to achieve the highest possible resolution. Here, a computational procedure was developed to compensate for the drift of the tube’s focal spot, geometrical imperfections of the LAD detector assembly, and the effects of its border pixels with different responses and sizes. We demonstrate the results on the final reconstructed images based on uncorrected and corrected projections, where we achieved a 1 μm voxel size.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20302 - Applied mechanics
Result continuities
Project
<a href="/en/project/EF16_019%2F0000766" target="_blank" >EF16_019/0000766: Engineering applications of microworld physics</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Volume of the periodical
13
Issue of the periodical within the volume
12
Country of publishing house
GB - UNITED KINGDOM
Number of pages
12
Pages from-to
—
UT code for WoS article
000452801600001
EID of the result in the Scopus database
2-s2.0-85059917084