System for Testing the Hygrothermal Performance of Multi-Layered Building Envelopes
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F02%3A01073907" target="_blank" >RIV/68407700:21110/02:01073907 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
System for Testing the Hygrothermal Performance of Multi-Layered Building Envelopes
Original language description
A measuring system for determination of temperature, moisture, relative humidity, capillary pressure and salinity profiles in building envelopes is presented in the paper. The system makes it possible to analyze the hygrothermal performance of either particular materials or the whole building envelopes in the conditions of difference climate
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
JN - Civil engineering
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2002
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Thermal Envelope & Building Science
ISSN
1097-1963
e-ISSN
—
Volume of the periodical
25
Issue of the periodical within the volume
1
Country of publishing house
GB - UNITED KINGDOM
Number of pages
11
Pages from-to
239-249
UT code for WoS article
—
EID of the result in the Scopus database
—