Application of Time Domain Reflectometry and Capacitance Methods for Moisture Measurement in Building Materials
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F05%3A01116194" target="_blank" >RIV/68407700:21110/05:01116194 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Application of Time Domain Reflectometry and Capacitance Methods for Moisture Measurement in Building Materials
Original language description
The time domain reflectometry method is applied for determination of moisture content in autoclaved aerated concrete (AAC) specimens. The same experiments are also performed with a capacitance method, for the sake of comparison. The measured results showthat both methods are well applicable for determination of moisture content in porous buildings materials.
Czech name
Použití TDR metody a kapacitní metody pro měření vlhkosti ve stavebních materiálech
Czech description
Metoda TDR je použita pro určení vlhkosti v pórobetonu. Stejné experimenty jsou provedeny pomocí kapacitní metody. Výsledky měření ukazují, že obě metody jsou pro sledování obsahu vlhkosti dobře použitelné.
Classification
Type
C - Chapter in a specialist book
CEP classification
JI - Composite materials
OECD FORD branch
—
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2005
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Book/collection name
Development of Experimental Methods for Evaluation of Functional Properties of Buildings II
ISBN
80-01-03384-8
Number of pages of the result
6
Pages from-to
—
Number of pages of the book
80
Publisher name
ČVUT
Place of publication
Praha