Estimating the air leakage rate in calculations of energy demand for space heating - comparison of a simplified and a more advanced method
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F08%3A00151377" target="_blank" >RIV/68407700:21110/08:00151377 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Estimating the air leakage rate in calculations of energy demand for space heating - comparison of a simplified and a more advanced method
Original language description
Air leakage rate of a low energy single-family house was calculated using the simplified method according to EN ISO 13790. Results of simplified calculations are compared to the results of dynamic simulation performed by means of a multi-zone nodal model. Identical airtightness and wind shielding of the building were used in both simplified and dynamic calculations. The results are compared and discussed.