System with scale and soil moisture sensor
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F09%3A00163999" target="_blank" >RIV/68407700:21110/09:00163999 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
System with scale and soil moisture sensor
Original language description
Calibration set is designed for the determination of parameters of any soil moisture sensors by two independent ways: gravimetric and time domain reflectometry. The system consists of datalogger CR10X, two 20kg loading cells as combined digital scale andTDR100 oscilloscope with TDR probe. Data of weight sample and soil moisture are acquired continuously as a cross reference to calibrated sensor.
Czech name
—
Czech description
—
Classification
Type
G<sub>funk</sub> - Functional sample
CEP classification
DA - Hydrology and limnology
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2009
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Internal product ID
ScaleTDR
Numerical identification
—
Technical parameters
Datalogger Campbell Scientific CR10X, oscilloscope TDR100 2 loading cells RS 632-742, calibrated sensor, rack mount construction
Economical parameters
na trhu neexistuje zařízení tohoto typu
Application category by cost
—
Owner IČO
68407700
Owner name
Fakulta stavební ČVUT v Paze
Owner country
CZ - CZECH REPUBLIC
Usage type
P - Využití výsledku jiným subjektem je v některých případech možné bez nabytí licence
Licence fee requirement
Z - Poskytovatel licence na výsledek nepožaduje v některých případech licenční poplatek
Web page
—