Original language description
In this paper there is pointed out the need to extend the tests of SFRC (Steel Fibre Reinforced Concrete) about tensile strengths. Diagram of resistance, which is shown in this paper, is the starting material for determining the tensile strength of steelfibre reinforced concrete. In the full paper there are shown the formulas for calculating the stress by which a manufacturer may expose document about the strength class at the creation of macro-crack and at agreed deflection ?t,1=3,5mm.