Temperatures and thermal boundary conditions in reverse channel connections to concrete filled steel sections during standard and natural fire tests

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F15%3A00231906" target="_blank" >RIV/68407700:21110/15:00231906 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.firesaf.2015.08.002" target="_blank" >http://dx.doi.org/10.1016/j.firesaf.2015.08.002</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.firesaf.2015.08.002" target="_blank" >10.1016/j.firesaf.2015.08.002</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Temperatures and thermal boundary conditions in reverse channel connections to concrete filled steel sections during standard and natural fire tests

  • Original language description

    The paper presents fire test and numerical simulation results of temperature distributions in reverse channel connections to concrete-filled tubular columns during standard and natural fire tests. The experiments included a furnace fire test with the composite frame subjected to increasing fire temperature according to the ISO 834 standard time-temperature curve and two natural fire tests in a full-scale structure including a cooling phase. These fire tests examined the effects of fire protection, different connection locations and different connection dimensions. Temperatures at different connection components were recorded. The recorded connection component temperatures were simulated by using the SAFIR fire engineering software to calibrate the thermal boundary conditions in different connection components. From the numerical simulation results, it has been concluded that radiation to the inner surfaces of the reverse channel and the adjacent part of the column tube is only from the

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    JM - Structural engineering

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    R - Projekt Ramcoveho programu EK

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Fire Safety Journal

  • ISSN

    0379-7112

  • e-ISSN

  • Volume of the periodical

    78

  • Issue of the periodical within the volume

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    16

  • Pages from-to

    55-70