Influence of Zinc Coating to a Temperature of Steel Members in Fire
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F15%3A00232545" target="_blank" >RIV/68407700:21110/15:00232545 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Influence of Zinc Coating to a Temperature of Steel Members in Fire
Original language description
This paper describes effect of hot dip galvanizing of steel structure surfaces to temperature of steel members in the fire conditions. Temperature of the set of specimens was measured during the second fire test at experimental building in Veseli nad Luznici. Experiment results show, that the zinc coating can reduce temperature in steel members especially in the first fifteen minutes of the fire. The paper describes specimens, which were used for fire test, shows testing procedure and compares measuredtemperatures of specimens with and without zinc coated surface. The paper also describes the process of analytical evaluation and based on the results of this evaluation specifies value of the surface emissivity for zinc coated steel members in the fireconditions.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
JN - Civil engineering
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Structural Fire Engineering
ISSN
2040-2317
e-ISSN
—
Volume of the periodical
6
Issue of the periodical within the volume
June
Country of publishing house
GB - UNITED KINGDOM
Number of pages
6
Pages from-to
141-146
UT code for WoS article
—
EID of the result in the Scopus database
—