Fouling of in-sewer heat exchangers: to oversize them or to clean them?
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F15%3A00241183" target="_blank" >RIV/68407700:21110/15:00241183 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Fouling of in-sewer heat exchangers: to oversize them or to clean them?
Original language description
In-sewer heat exchangers are subject to fouling reducing heat transfer efficiency. Biofilm growth and renewal after mechanical cleaning as well as probability of biofilm scouring by storm events were studied by combination of biofilm sampling and shear stress modelling. The amount of biofilm decreases with increasing shear untouched tress in the sewer. In sewers with high shear stress (25-32 N/m2) cleaning has no effect as biofilm renewal occurs in less than 2 weeks. In sewers with lower shear stress (4-6 N/m2), cleaning 1 per 2 weeks reduces the amount of biofilm and sediments to about a half. Self-cleansing of heat exchangers during storm events can substitute the cleaning only in summer and in a very limited number of sewers. Cost analysis showed that the smaller the heat exchanger area, the better the strategy to oversize it than to clean it. The necessary oversizing can be derived for a given heat exchanger type and cleaning costs.
Czech name
—
Czech description
—
Classification
Type
O - Miscellaneous
CEP classification
—
OECD FORD branch
10511 - Environmental sciences (social aspects to be 5.7)
Result continuities
Project
<a href="/en/project/TA03020600" target="_blank" >TA03020600: Heat recovery from wastewater in combined sewer systems (enKAN)</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů