Drying Shrinkage of Concrete Elements

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F17%3A00242989" target="_blank" >RIV/68407700:21110/17:00242989 - isvavai.cz</a>

  • Result on the web

    <a href="http://onlinelibrary.wiley.com/doi/10.1002/suco.201500208/abstract" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1002/suco.201500208/abstract</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/suco.201500208" target="_blank" >10.1002/suco.201500208</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Drying Shrinkage of Concrete Elements

  • Original language description

    The paper deals with shrinkage of large concrete specimens. The segments of walls of the thicknesses 200 mm, 400 mm and 800 mm were cast. Four sides were sealed in order to simulate the drying of the infinite walls of different thicknesses. The elements are equipped with vibrating wire strain gauges which measure strains inside the elements. The strains in vertical as well as in horizontal directions have been recorded for the period of 6 months. The segments of walls are stored in a laboratory. Relative humidity and temperature of the environment are not controlled, but recorded very closely. Additional tests have been executed. The concrete compression strength was measured on cubes and uniaxial shrinkage is measured on standard cylinders using embedded vibrating wire strain gauges. The cylinders are stored in three different environments, in the laboratory and in the rooms with controlled relative humidity of 65 % and 100 %, respectively. A comparison of measured shrinkage with various shrinkage models is provided (Model Code 2010, Eurocode 2, Model B3, Model B4, Model B4s and Model ACI 209R-92).

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20101 - Civil engineering

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Structural Concrete

  • ISSN

    1464-4177

  • e-ISSN

    1751-7648

  • Volume of the periodical

    18

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    12

  • Pages from-to

    92-103

  • UT code for WoS article

    000398106800011

  • EID of the result in the Scopus database

    2-s2.0-85016077525